Equipment
Microscope Axio Imager M2
Contact person:
Waliczek Marta
Technical description:
Polarizing microscope for observation in transmitted and reflected light with digital camera and image analysis software, with system for vitrinite reflectance measurement is part of an organic matter research system: Rock-Eval 7S pyrolytic apparatu…
Rock-Eval 7S
Contact person:
Więcław Dariusz
Technical description:
The Rock-Eval 7S pyrolytic apparatus is part of an organic matter research system: Rock-Eval 7S pyrolytic apparatus completed with a polarizing microscope unit for studies in reflected light, equipped with a photometer for reflectance measurements.
…
Soxtec 2055
Contact person:
Więcław Dariusz
Technical description:
The Soxtec Avanti 2055 extraction system makes it possible to perform extractions using a wide range of solvents, in a faster, safer and more economical way compared to Soxhlet extraction. Extraction time is reduced to 20% of Soxhlet extraction time…
Set for hydrous pyrolysis experiments
Contact person:
Więcław Dariusz
Technical description:
The hydrous pyrolysis (HP) system is unique not only in Poland, but also in Europe. HP is an advanced experimental method for the simulation of natural processes of thermal transformation of organic matter and formation of hydrocarbons. The nature o…
Pyrolizer
Contact person:
Kowalski Adam
Technical description:
Pyrolysis is heating large complex molecules in the absence of air to break them down into smaller, more analytically available fragments. Combined with GC/MS, pyrolysis enables quantitative and qualitative analysis of complex samples without extend…
Density meter DMA 4500 M
Contact person:
Więcław Dariusz
Technical description:
Aparatures measures the density at temperatures between -10 °C and 200 °C and elevated pressures up to 500 bar. The automatic bubble detection, FillingCheck™, makes the DMA 4200 M compliant with ASTM D4052 and ASTM D5002. Viscosity inf…
Delta V Plus Spectrometer
Contact person:
Kowalski Tomasz
Technical description:
The device is used to measure the composition of stable isotopes of light elements with masses from 10 to 80 Da and additionally hydrogen (mass 2 and 3 Da) using the differential method. The principle of the operation consists in separating individu…
GC-FID
Contact person:
Kowalski Adam
Technical description:
Gas chromatography with FID detector allows for determining the composition of fuels and chemicals and studying air, water and soil pollution (BTEX).
GC/MS
Contact person:
Kowalski Adam
Technical description:
GC/MSD is a reliable tool for studying environmental and food contaminants, chemical and petrochemical, toxicology and pharmaceutical research analyses.
GC-FID/TCD
Contact person:
Bilkiewicz Elżbieta
Technical description:
The chromatograph is equipped with a set of columns and two detectors: (FID) flame ionization detector and (TCD) thermal conductivity detector. The chromatograph is equipped with three valves to which three packed columns of 1/8” (0.9 m H…